Non-contact temperature measurement of silicon wafers based on the combined use of transmittance and radiance

Yuki Toyoda,Tomohiro Seo,Tohru Iuchi
DOI: https://doi.org/10.1016/j.measurement.2014.02.023
IF: 5.6
2014-05-01
Measurement
Abstract:We propose a non-contact temperature measurement method that combines the temperature dependence of transmittance below 600°C and radiation thermometry above 600°C. The combined method uses a polarization technique and the Brewster angle between air and a dielectric film such as SiO2 or Si3N4 grown on silicon wafers. A prominent feature of this method is that both measurements of transmittance and radiance are performed with the same geometrical arrangement.For a semitransparent wafer, the measurement of p-polarized transmittance at the wavelengths of 1.1, 1.2 and 1.3μm enables temperature measurement in the range from room temperature to 600°C. For an opaque wafer above 600°C, the p-polarized radiation thermometry at the wavelength of 4.5μm allows the temperature measurement without the emissivity problem. The combined method with the use of transmittance and radiance is valid in the entire temperature range irrespective of variations of film thickness and resistivity.
engineering, multidisciplinary,instruments & instrumentation
What problem does this paper attempt to address?