First Wall and Blanket Design for a High Wall Loading Compact Tokamak Power Reactor

I.N. Sviatoslavsky,S.I. Abdel-Khalik,M.L. Corradini,L.J. Wittenberg,G.L. Kulcinski,K.Y. Huh,M. El-Afify
DOI: https://doi.org/10.13182/fst85-a40161
1985-07-01
Fusion Technology
Abstract:Among the specific limitations which tend to complicate a compact high wall loading (HWL) tokamak reactor design are high surface and nuclear heating, compactness leading to crowded components, unlikely breeding on the inboard side and frequent first wall/blanket replacement. This paper describes the mechanical, thermal hydraulic and tritium aspects of an improved blanket design for a high β (20%), high wall loading (∼ 10 MW/m2) compact fusion power reactor of 1000 MWth power output.
What problem does this paper attempt to address?