The role of titanium in the initiation of localized corrosion of stainless steel 444

Samantha Michelle Gateman,Lisa Irene Stephens,Samuel Charles Perry,Robert Lacasse,Robert Schulz,Janine Mauzeroll
DOI: https://doi.org/10.1038/s41529-018-0026-5
2018-02-14
npj Materials Degradation
Abstract:Titanium has been added to ferritic stainless steels to combat the detrimental effects of intergranular corrosion. While this has proven to be a successful strategy, we have found that the resulting Ti-rich inclusions present on the surface play a significant role in the initiation of other forms of localized corrosion. Herein, we report the effect of these inclusions on the localized corrosion of a stainless steel using macro and micro electrochemical techniques. Through the use of scanning electrochemical microscopy, we observe the microgalvanic couple formed between the conductive inclusions and passivated metal matrix. The difference in local reactivity across the material’s surface was quantified using a 3D finite element model specifically built to respect the geometry of the corrosion-initiating features. Combined with electron microscopy and micro elemental analysis, localization of other alloying elements has been reported to provide new insight on their significance in localized corrosion resistance.
materials science, multidisciplinary
What problem does this paper attempt to address?