Intraocular Lens Position and Anterior Chamber Parameters Evaluation After Nd:YAG Laser Posterior Capsulotomy for Posterior Capsular Opacification Using Anterior Segment Swept-Source Optical Coherence Tomography
Marina Delgado João,Jorge Vasco Costa,Tiago Monteiro,Nuno Franqueira,Fernando Faria Correia,Fernando Vaz,Marina Delgado João
DOI: https://doi.org/10.2147/OPTH.S349649
2022-01-19
Clinical Ophthalmology
Abstract:Marina Delgado João, Jorge Vasco Costa, Tiago Monteiro, Nuno Franqueira, Fernando Faria Correia, Fernando Vaz Ophthalmology Department, Hospital de Braga, Braga, Portugal Correspondence: Marina Delgado João, Tel +351 253 027 000 , Fax +351 253 027 999 , Email Purpose: To evaluate the effect of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy on intraocular lens (IOL) position and anterior segment parameters with a new swept-source anterior segment optical coherence tomography (AS-OCT) device (Anterion ® , Heidelberg Engineering GmbH). Patients and Methods: A total of 50 eyes from 50 consecutive patients were included. All patients had visually significant posterior capsular opacification (PCO) after uneventful phacoemulsification surgery with manual capsulorhexis and single-piece C-loop acrylic IOL implantation (AcrySof ® SA60AT) and were treated with Nd:YAG laser. Anterior segment images were captured with Anterion ® in non-dilated conditions before and one month after the procedure. In the "Metrics App", we collected data of the anterior chamber angle (ACA) 3 and 9 o'clock, the anterior chamber depth (ACD), the anterior chamber volume (ACV), and the central corneal thickness (CCT). We also collected demographic and clinical data [age, gender, months from surgery to Nd: YAG capsulotomy, pre- and post-capsulotomy corrected distance visual acuity (CDVA) and spherical equivalent, and axial length]. Results: We did not find a statistically significant difference in ACD after the Nd:YAG capsulotomy (3.96 ± 0.55 vs 3.97 ± 0.55 mm, p = 0.10). In 28 patients, we noted a backward movement of the IOL; in the remaining 22, the IOL moved forward or did not change at all. We did not observe significant changes in ACA at the 3 and 9 o'clock reference points, ACV, or CCT. There was an improvement in CDVA after the procedure (0.37 ± 0.21 vs 0.12 ± 0.27 logMAR, p = 0.015), without statistically significant differences in SE (? 0.15 ± 0.84 vs ? 0.25 ± 0,93, p = 0.42). Axial length was not correlated with ACD variations after the procedure (p = 0.67). Conclusion: Our results show that Nd:YAG laser capsulotomy does not change the axial position of a single-piece C-loop acrylic IOL inside the capsular bag, as well as other anterior chamber parameters. Keywords: neodymium-doped yttrium aluminum garnet laser, capsulotomy, posterior capsular opacification, intraocular lens, swept-source anterior segment optical coherence tomography Neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy is the gold-standard technique for treating posterior capsular opacification (PCO) in pseudophakic patients, which still represents the most common long-term postoperative complication after cataract surgery. 1 Nonetheless, PCO overall incidence has decreased from 50% in the 1980s to up to 10–20% today. 2,3 Despite having a success rate of more than 95%, Nd:YAG capsulotomy is also associated with multiple complications, such as intraocular pressure (IOP) spikes, corneal damage, uveitis, anterior hyaloid disruption, cystoid macular edema, intraocular lens (IOL) damage, movement, or dislocation, and refractive changes. 4,5 Findl et al 6 reported a posterior IOL displacement after the procedure, which caused a visually significant hyperopic shift, especially in those with larger capsulotomies. Previous studies have addressed the change in IOL position and anterior chamber parameters following Nd:YAG treatment, with mixed results. 7–12 However, most of these studies present relevant limitations. Some studies included a mixed group of patients submitted to phacoemulsification surgery or extracapsular cataract extraction, while others included eyes that had been implanted with different IOLs. In this study, we evaluated the effective lens position and anterior chamber parameters before and after Nd:YAG capsulotomy in patients with PCO after uneventful phacoemulsification cataract surgery and single-piece C-loop IOL implantation. All parameters were obtained with a novel high-resolution swept-source anterior segment optical coherence tomography (AS-OCT) device (Anterion ® , Heidelberg Engineering GmbH, Heidelberg, Germany). This prospective study conformed to the tenets of the Declaration of Helsinki. Full ethical approval from the Ethical Commission of Hospital de Braga was obtained. All patients signed an informed consent after a careful explanation of the procedure and before the interventions were performed. 50 eyes from 50 consecutive patients were included. All patients had visually significant PCO after uneventful phacoemulsification surgery with manual capsulorhexis and single-piece acrylic IOL implantation (AcrySof ® SA60AT, A -Abstract Truncated-