INVESTIGATION CORROSION BEHAVIOUR OF DUCTILE CAST IRON WELD JOINT IN SEA WATER

Khairia S Hassan,Yusra M Alamran,Huda M Abdulaziz
DOI: https://doi.org/10.32852/iqjfmme.vol18.iss1.65
2018-07-31
THE IRAQI JOURNAL FOR MECHANICAL AND MATERIALS ENGINEERING
Abstract:Manual metal-arc welding was carried out for ductile cast iron under welding conditionsof (90) A DC current (DCEN) and 20 volts. Welding wire type E- Ni -Fe- CI in diameter of3.2mm was used and travel speed of 7 inch /min and welded through two passes. The weldjoined are examined using X-ray radiography, broken down joint are excepted. Corrosionspecimens prepared from free defects joints having measurements of (15*15*3) mmagreeing to ASTM G71-31. Then Optical microscopy was employed to detect the weldedjoint microstructure and base metal. Micro hardness was implemented using Vickers test.Corrosion examinations are conducted using electrochemical potential state chamber inequipped (sea water 3.5% NaCl),Corrosion examination is achieved using potentiostaticpolarization dimensions in saltwater 3.5%NaCl at potential scan rate (+100-100 mv/sec) toestimate corrosion parameters by extrapolating. The corrosion rate was calculated by Tafelequation. The results of corrosion rate can be predicted using a mathematical model usingdata achieved from practical method and compare these results with the theoretical one,results show that corrosion rate for welded joint is more than the base metal because of thechange in metal microstructure during welding process.
What problem does this paper attempt to address?