Multi-laboratory evaluation of the Illumina iSeq platform for whole genome sequencing of Salmonella, Escherichia coli and Listeria
Patrick K. Mitchell,Leyi Wang,Bryce J. Stanhope,Brittany D. Cronk,Renee Anderson,Shipra Mohan,Lijuan Zhou,Susan Sanchez,Paula Bartlett,Carol Maddox,Vanessa DeShambo,Rinosh Mani,Lindsy M. Hengesbach,Sarah Gresch,Katie Wright,Sunil Mor,Shuping Zhang,Zhenyu Shen,Lifang Yan,Rebecca Mackey,Rebecca Franklin-Guild,Yan Zhang,Melanie Prarat,Katherine Shiplett,Akhilesh Ramachandran,Sai Narayanan,Justin Sanders,Andree A. Hunkapiller,Kevin Lahmers,Amanda A. Carbonello,Nicole Aulik,Ailam Lim,Jennifer Cooper,Angelica Jones,Jake Guag,Sarah M. Nemser,Gregory H. Tyson,Ruth Timme,Errol Strain,Renate Reimschuessel,Olgica Ceric,Laura B. Goodman
DOI: https://doi.org/10.1099/mgen.0.000717
IF: 4.868
2022-02-03
Microbial Genomics
Abstract:There is a growing need for public health and veterinary laboratories to perform whole genome sequencing (WGS) for monitoring antimicrobial resistance (AMR) and protecting the safety of people and animals. With the availability of smaller and more affordable sequencing platforms coupled with well-defined bioinformatic protocols, the technological capability to incorporate this technique for real-time surveillance and genomic epidemiology has greatly expanded. There is a need, however, to ensure that data are of high quality. The goal of this study was to assess the utility of a small benchtop sequencing platform using a multi-laboratory verification approach. Thirteen laboratories were provided the same equipment, reagents, protocols and bacterial reference strains. The Illumina DNA Prep and Nextera XT library preparation kits were compared, and 2×150 bp iSeq i100 chemistry was used for sequencing. Analyses comparing the sequences produced from this study with closed genomes from the provided strains were performed using open-source programs. A detailed, step-by-step protocol is publicly available via protocols.io ( https://www.protocols.io/view/iseq-bacterial-wgs-protocol-bij8kcrw ). The throughput for this method is approximately 4–6 bacterial isolates per sequencing run (20–26 Mb total load). The Illumina DNA Prep library preparation kit produced high-quality assemblies and nearly complete AMR gene annotations. The Prep method produced more consistent coverage compared to XT, and when coverage benchmarks were met, nearly all AMR, virulence and subtyping gene targets were correctly identified. Because it reduces the technical and financial barriers to generating WGS data, the iSeq platform is a viable option for small laboratories interested in genomic surveillance of microbial pathogens.
microbiology,genetics & heredity