Abstract:Purpose The purpose of this paper is to establish the horizontal displacement angle limit values under different performance level, use damage as the quantitative index of performance level and determine the design principle of the RACFST column for performance-based seismic fortification target based on the damage. Design/methodology/approach The paper is based on the seismic performance test of the RACFST column. Findings First, three-level seismic are introduced into the performance design foundation of the RACFST column. Second, the performance level of the RACFST column is divided into five grades: normal use, temporary use, use after repair, life safety and prevention of collapse. Third, the seismic performance targets of RACFST columns are divided into four categories: unacceptable situation, basic performance target, important performance target and special performance target. Originality/value The initial damage of the recycled aggregate occurs in the process of crushing and screening, and the damage evolution and development of the RACFST column occur under cyclic load. This is one of the problems that should not be avoided in the design of the seismic performance of the RACFST column. New levels are introduced in the performance design foundation of the RACFST column.
What problem does this paper attempt to address?