Effect of Porosity of the regenerator on the performance of a miniature Stirling cryocooler

Shital Kumar Garg,B. Premachandran,Manmohan Singh,Sunil Sachdev,Mukesh Sadana
DOI: https://doi.org/10.1016/j.tsep.2019.100442
IF: 4.56
2020-03-01
Thermal Science and Engineering Progress
Abstract:<p>The performance of miniature Stirling cryocooler depends primarily on the porosity of wire-meshes used in the regenerator. Low porosity regenerator requires higher input power to get the same pressure ratio to compress the working fluid due to a higher pressure drop compared to that of a high porosity regenerator. On the other hand, high porosity regenerator requires less power input. However, the thermal performance of the regenerator decreases as the porosity increases. In the present experimental study, uniform porosity and non-uniform porosity matrices were considered to obtain an optimum porous matrix of the regenerator for the cooling capacity of 0.5W @80K with Helium as the working fluid. In the parametric study, for the regenerator with the uniform porosity, the wire-mesh number of 200, 300, 400 and 500 are considered. Based on the cool-down time and power input, wire-mesh number 400 is considered to be optimum. For the reduction of cool-down time and power consumption, non-uniform porous matrix regenerators were considered with different combinations of wire meshes for a miniature Stirling cryocooler. Present study shows that non-uniform porous matrices reduce the power consumption or cool-down time considerably compared to the uniform porous matrix of the miniature Stirling cryocooler.</p>
What problem does this paper attempt to address?