Effect of hydrostatic pressure on the galvanic corrosion of 90/10 Cu-Ni alloy coupled to Ti6Al4V alloy

Shengbo Hu,Rui Liu,Li Liu,Yu Cui,Emeka E. Oguzie,Fuhui Wang
DOI: https://doi.org/10.1016/j.corsci.2019.108242
IF: 7.72
2020-02-01
Corrosion Science
Abstract:The corrosion of 90/10 Cu-Ni coupled to Ti6Al4V in 3.5% NaCl solution at different hydrostatic pressures was investigated by means of electrochemical methods, weight loss experiment, SEM/EDS, finite element analysis, etc. The 90/10 Cu-Ni was always found to be the anode part in the galvanic cell at all pressures studied. The galvanic current density and natural corrosion current density of 90/10 Cu-Ni during coupling to Ti6Al4V were both increased with increasing hydrostatic pressure, which resulted in an obvious increase of the total corrosion rate of 90/10 Cu-Ni.
materials science, multidisciplinary,metallurgy & metallurgical engineering