The Study of Corrosion Behavior and Hardness of AISI Stainless Steel 304 in Concentration of Chloride Acid Solution and Temperature Variations

I Saefuloh,N Kanani,F Gumelar Ramadhan,Y Rukmayadi,Y Yusuf,Syarif Abdullah,Sidik Susilo
DOI: https://doi.org/10.1088/1742-6596/1477/5/052058
2020-03-01
Journal of Physics: Conference Series
Abstract:Abstract This research aims at investigating the corrosion behavior and hardness of AISI Stainless Steel 304 (AISI SS 304) in corrosive hydrochloric acid solution and temperature variation treatment. In this study, the samples of AISI SS 304 are immersed for six (6) days in the corrosive acid solution at the temperature of 30°C and 50°C. The solution used as the corrosive media are HCl, FeCl3, and NaCl in the concentration of 5%, 10% and 15%. The results show that the higher the concentration of the solution, the higher the corrosion rate of AISI SS 304 will be, and the higher the temperature, the higher corrosion rate will also occur in all corrosion media. The corrosion that occurs in AISI SS 304 is mostly in the form of uniform corrosion and some pitting corrosion, and the value of hardness decreases after corrosion.
What problem does this paper attempt to address?