Determination and Identification of Nickel(II) Spectroscopy in Alloy Samples Using Chromogenic Reagent(HPEDN)

Esraa Raafid,Muneer A. Al-Da’amy,Salih Hadi Kadhim
DOI: https://doi.org/10.1088/1757-899x/871/1/012025
2020-06-01
IOP Conference Series: Materials Science and Engineering
Abstract:Abstract A modern and easy procedure performed using the spectrophotometric method and estimating of Ni (II) in alloy samples. Using a ligand 1-((4-(1-(2-hydroxyphenylimino) ethyl)phenyl)diazenyl)naphthalene-2-ol (HPEDN) and a synthesis of the azo-schiff reaction by reaction p-aminoacetophenone with 2-naphtol in first step and reaction of product with 2-aminonaphthol, Ligand and its complex were identification by using UV-Vis. Spectrophotometry (326nm for ligand (HPEDN), 516nm for complex(Ni-HPEDN)), FT-IR, 1 H-NMR, and 13 C-NMR. The optimal conditions in the complex composition were studied at pH=9, temperature 25°C, and time 15min. The best concentration was found for Ligand (2×10 −4 M), Under optimum conditions concentration ranged from (1.1-7.1) μg/mL of Nickel(II) were obeyed Beer‘s Low, with Molar Absorptivity 0.2648×10 4 L.mol −1 .cm −1 . Limit of Detection(LOD) and Limit of Quantification(LOQ)were 0.3928 and 1.3082μg.mL −1 respectively. The stoichiometric composition of the chelate is 1:2 (Ni:HPEDN). This method is Sensitive, accurate and rapid spectrophotometric method. The results obtained were compared with flame atomic absorption spectrometry method and results are in conformity.
What problem does this paper attempt to address?