Strength Degradation in Curved Fiber-reinforced Polymer (FRP) Bars Used as Concrete Reinforcement

Thanongsak Imjai,Reyes Garcia,Maurizio Guadagnini,Kypros Pilakoutas
DOI: https://doi.org/10.3390/polym12081653
IF: 5
2020-07-24
Polymers
Abstract:Steel reinforcements in concrete tend to corrode and this process can lead to structural damage. Fiber-reinforced polymer (FRP) reinforcements represent a viable alternative for structures exposed to aggressive environments and have many possible applications where superior corrosion resistance properties are required. The use of FRP rebars as internal reinforcements for concrete, however, is limited to specific structural elements and does not yet extend to the whole structure. The reason for this relates to the limited availability of curved or shaped reinforcing FRP elements on the market, as well as their reduced structural performance. This article presents a state-of-the art review on the strength degradation of curved FRP composites, and also assesses the performance of existing predictive models for the bend capacity of FRP reinforcements. Previous research has shown that the mechanical performance of bent portions of FRP bars significantly reduces under a multiaxial combination of stresses. Indeed, the tensile strength of bent FRP bars can be as low as 25% of the maximum tensile strength developed in a straight counterpart. In a significant number of cases, the current design recommendations for concrete structures reinforced with FRP were found to overestimate the bend capacity of FRP bars. A more accurate and practical predictive model based on the Tsai–Hill failure criteria is also discussed. This review article also identifies potential challenges and future directions of research for exploring the use of curved/shaped FRP composites in civil engineering applications.
polymer science
What problem does this paper attempt to address?
This paper aims to solve the problem of strength degradation when fiber - reinforced polymer (FRP) rebars are used in bending in concrete structures. Specifically, the paper focuses on the significant decline in the mechanical properties of bent FRP rebars under multi - axial stress combinations, especially the problem of premature failure that is likely to occur at the bent corners. Research shows that the tensile strength of the bent part of FRP rebars may be as low as 25% of the maximum tensile strength of straight rebars. In addition, current design recommendations may overestimate the bending capacity of FRP rebars, so more accurate prediction models are required to evaluate the bending capacity of FRP rebars. The paper also discusses a prediction model based on the Tsai - Hill failure criterion and points out the directions for future research to explore the potential of bent/ shaped FRP composites in civil engineering applications.