Effects of varying chest compression depths on carotid blood flow and blood pressure in asphyxiated piglets

Marlies Bruckner,Megan O’Reilly,Tze-Fun Lee,Mattias Neset,Po-Yin Cheung,Georg M Schmölzer
DOI: https://doi.org/10.1136/archdischild-2020-319473
2021-02-04
Abstract:Background Current neonatal resuscitation guidelines recommend chest compressions (CCs) should be delivered to a depth of approximately 1/3 of the anterior–posterior (AP) chest diameter. The aim of the study was to investigate the haemodynamic effects of different CC depths in a neonatal piglet model. Methods CCs were performed with an automated CC machine with 33%, 40% and 25% AP chest diameter in all piglets in the same order for a duration of 3 min each. Results Eight newborn piglets (age 1–3 days, weight 1.7–2.3 kg) were included in the study. Carotid blood flow (CBF) and systolic blood pressure were the highest using a CC depth of 40% AP chest diameter (19.3±7.5 mL/min/kg and 58±32 mm Hg). Conclusion CC depth influences haemodynamic parameters in asphyxiated newborn piglets during cardiopulmonary resuscitation. The highest CBF and systolic blood pressure were achieved using a CC depth of 40% AP chest diameter. Trial registration number PCTE0000148.
What problem does this paper attempt to address?