A Selective Ratiometric Fluorescent Probe for No-Wash Detection of PVC Microplastic

Valeria Caponetti,Alexandra Mavridi-Printezi,Matteo Cingolani,Enrico Rampazzo,Damiano Genovese,Luca Prodi,Daniele Fabbri,Marco Montalti
DOI: https://doi.org/10.3390/polym13101588
IF: 5
2021-05-14
Polymers
Abstract:Microplastics (MP) are micrometric plastic particles present in drinking water, food and the environment that constitute an emerging pollutant and pose a menace to human health. Novel methods for the fast detection of these new contaminants are needed. Fluorescence-based detection exploits the use of specific probes to label the MP particles. This method can be environmentally friendly, low-cost, easily scalable but also very sensitive and specific. Here, we present the synthesis and application of a new probe based on perylene-diimide (PDI), which can be prepared in a few minutes by a one-pot reaction using a conventional microwave oven and can be used for the direct detection of MP in water without any further treatment of the sample. The green fluorescence is strongly quenched in water at neutral pH because of the formation dimers. The ability of the probe to label MP was tested for polyvinyl chloride (PVC), polyethylene (PE), polyethylene terephthalate (PET), polypropylene (PP), polystyrene (PS), poly methyl methacrylate (PMMA) and polytetrafluoroethylene (PTFE). The probe showed considerable selectivity to PVC MP, which presented an intense red emission after staining. Interestingly, the fluorescence of the MP after labeling could be detected, under excitation with a blue diode, with a conventional CMOS color camera. Good selectivity was achieved analyzing the red to green fluorescence intensity ratio. UV–Vis absorption, steady-state and time-resolved fluorescence spectroscopy, fluorescence anisotropy, fluorescence wide-field and confocal laser scanning microscopy allowed elucidating the mechanism of the staining in detail.
polymer science
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a fast, simple and fluorescence probe method without washing steps for detecting polyvinyl chloride (PVC) microplastics in water. Specifically, the researchers designed and synthesized a ratiometric fluorescence probe based on perylene diimide (PDI), which can directly label PVC microplastics in a neutral aqueous solution, thereby achieving specific detection of PVC microplastics. This method is not only environmentally friendly and low - cost, but also has high sensitivity and selectivity, and can directly detect the fluorescence signal of microplastics in the staining solution without any cleaning or further sample processing. The key point of the paper lies in using the aggregation effect of the PDI probe to achieve selective detection of microplastics. In a neutral aqueous solution, the probe molecules will form almost completely quenched dimers and do not generate background signals; when adsorbed onto PVC microplastics, the probe molecules will depolymerize and turn on red fluorescence, thereby achieving specific detection of PVC microplastics. This mechanism enables PVC microplastics to be easily identified under a conventional fluorescence microscope, providing a new tool for environmental monitoring.