Effect of current density on groundwater arsenite removal performance using air cathode electrocoagulation

Yanxiao Si,Fang Zhang,Chen Hong,Guanghe Li,Haichuan Zhang,Dun Liu
DOI: https://doi.org/10.1007/s11783-021-1399-1
2021-02-28
Abstract:Naturally occurring arsenic enrichment in groundwater poses a huge threat to human health. Air cathode electrocoagulation (ACEC) has recently been proposed to enhance As(III) oxidation and lower energy consumption. In this study, ACEC, EC/O<sub>2</sub> and EC/N<sub>2</sub> were evaluated with different current densities from 1 to 8 mA/cm<sup>2</sup> to investigate the effect on As(III) removal in different redox environments. Current density had no appreciable effect on arsenic removal efficiency given the same charge in ACEC because the concentration ratio of Fe/H<sub>2</sub>O<sub>2</sub> under different current densities remained stable. However, in EC/O<sub>2</sub> and EC/N<sub>2</sub>, As(III) removal was inhibited at higher current densities (4–8 mA/cm<sup>2</sup>), likely because more Fe(II) competed with As(III) for the oxidant, leading to less effective oxidation of As(III). In all EC systems, the ·OH units generated per power consumption reached the highest value at the lowest current density. Compared with other EC systems, the ACEC system showed lower energy consumption at all current densities due to the low energy consumption of the electrode reaction and more free radical generation. A lower current density saved more energy at the expense of time, showing the trade-off relationship between energy consumption and removal time. The operation costs for As(III) removal under optimal conditions were calculated as 0.028 $/m<sup>3</sup> for ACEC, 0.030 $/m<sup>3</sup> for EC/O<sub>2</sub>, and 0.085 $/m<sup>3</sup> for EC/N<sub>2</sub>
environmental sciences,engineering, environmental
What problem does this paper attempt to address?
This paper aims to explore the influence of current density on the performance of removing arsenide (As(III)) in groundwater using the air - cathode electrocoagulation (ACEC) technique. Specifically, the study compared the effects of different current densities (1 to 8 mA/cm²) on the As(III) removal efficiency and energy consumption in different redox environments (such as aerobic EC systems (EC/O₂) and anaerobic EC systems (EC/N₂)). Through experiments, the paper analyzed the generation rate of free radicals (·OH) in the ACEC system and the removal rate of As(III), and explored the trade - off relationship between current density, energy consumption and removal time, providing strategic suggestions for operating the EC system with high efficiency in practical operations. The main findings of the paper include: 1. Under the same amount of charge, the As(III) removal efficiency of the ACEC system is less affected by the current density, which is attributed to the stable ratio of H₂O₂/Fe(II) generated at different current densities. 2. Compared with the EC/O₂ or EC/N₂ systems, the ACEC system shows lower energy consumption at all tested current densities. 3. In the ACEC system, as the current density increases from 1 to 8 mA/cm², the concentration of ·OH per unit of energy consumption first increases and then decreases, and reaches the maximum at 1 mA/cm², indicating that a lower current density helps to save energy at the cost of sacrificing the treatment time. 4. The study also revealed the trade - off relationship between current density, As(III) removal time and energy consumption in different EC systems, pointing out that although a low current density prolongs the treatment time, it has a significant advantage in energy saving. In conclusion, this study provides a scientific basis for optimizing the selection of current density in the treatment process of high - arsenic groundwater, and emphasizes the importance of balancing treatment efficiency and energy consumption in practical applications.