Arsenic Removal in Synthetic Ground Water Using Iron Electrolysis

Lei Li,Jun Li,Chen Shao,Kejia Zhang,Shuili Yu,Naiyun Gao,Yang Deng,Daqiang Yin
DOI: https://doi.org/10.1016/j.seppur.2013.11.012
IF: 8.6
2014-01-01
Separation and Purification Technology
Abstract:Electrocoagulation (EC) using electrodes made from iron scrap is a novel and promising strategy for arsenic (As) contaminated ground water remediation. In synthetic groundwater, amorphous hydrous ferric oxide (HFO) precipitates formed by the rapid dissolution of a sacrificial iron scrap anode adsorbed As very effectively. A competitive adsorption model developed in this study with parameters fitted for As and other coexisting anions (phosphate and silicate) was in good agreement with the observed results. It is indicated that the maximum adsorption capacity of HFO generated in the EC system was ∼0.70mol/mol. Reducing the As concentration in water from 500μg/L As(V) and As(III) to below 50μg/L (local drinking water standard in Bangladesh) required ∼8mg/L and ∼32mg/L iron respectively (pH=7.1±0.1, charge dosage rate=3 coulomb/L/min). It was found that coexisting cations (Ca2+ and Mg2+) neutralized the HFO surface charge, promoted aggregation and resulted in greater As removal. The presence of humic acid exhibited a negligible effect on As removal and HFO precipitate settling. Jar tests showed that the turbidity of the solution could be reduced to <1 NTU with the addition of 2mg/L Al3+.
What problem does this paper attempt to address?