Improved recovery of fluoride in plant material using a low temperature sealed chamber digestion technique in conjunction with a fluoride ion‐specific electrode

G. Keerthisinghe,M.J. McLaughlin,P.J. Randall
DOI: https://doi.org/10.1080/00103629109368539
1991-11-01
Communications in Soil Science and Plant Analysis
Abstract:Seven different sample preparation methods (five ashing and fusion methods, an acid digestion method, an oxygen flask combustion method) and the AOAC extraction method (975.04) were compared with a newly developed sealed chamber digestion method for the determination of fluoride (F) in vegetation. Subterranean clover tissue was the test material. Fluoride concentration in digests was measured using a F ion‐selective electrode. The sealed chamber digestion carried out with nitric acid in Teflon chambers at 120°C for 6 hours gave the highest F concentration in the plant material and the highest recovery of added F of all methods. Tests on several types of plant material confirmed the superiority of the closed chamber digestion. The superiority of the method is attributed to the complete solubilisation of F in the sample and elimination of losses of volatile F.
plant sciences,soil science,agronomy,chemistry, analytical
What problem does this paper attempt to address?