Local Corrosion of Aluminum of High Purity during Anodizing (Continued)

Toshiro FUKUSHIMA,Susumu KAWAKAMI,Yasuto TOGAWA
DOI: https://doi.org/10.4139/sfj1950.19.276
1968-01-01
Journal of the Metal Finishing Society of Japan
Abstract:Aluminum foil of 99.99% in purity was anodized in aqueous solution of sulfamic acid (1-10%, 20-50°C) under d.c. of 0.1-1.5A/dm2 and local corrosion of anode during anodizing was examined. It was found that the corrosion more occurred, resulting the decrease in coating ratio at lower temperature or lower concentration of electrolytic bath or under higher current density. Loss of metal during anodizing was independent of the occurrence of corrosion. The critical current density for the occurrence of corrosion depended upon surface conditioning of aluminum. The addition of 0.2-1.0% of sodium bichromate to 5% sulfamic acid bath at 30°C was effective for preventing the corrosion. However, the addition of 0.1% of sodium bichromate, 0.1-1.0% of quinoline, or 0.1-0.5% of sodium hexametaphosphate was detrimental to that prevention.