A pilot-scale wastewater reclamation system based on direct descending filtration and chlorine disinfection

Marília Vasconcellos Agnesini,Fernando Afonso Marrengula,Guilherme Sgobbi Zagui,Cristina Filomena Pereira Rosa Paschoalato,Murilo Daniel de Mello Innocentini
DOI: https://doi.org/10.1016/j.jece.2024.112165
IF: 7.7
2024-02-11
Journal of Environmental Chemical Engineering
Abstract:The development of cost-effective technologies for treating and disinfecting wastewater to a level that makes it economically valuable, environmentally sustainable, and health-safe for reuse is of utmost importance. In this study, a direct descending filtration pilot unit was designed, assembled, and tested within a municipal wastewater treatment plant to produce nonpotable reclaimed wastewater. Bench-scale tests were performed to define the optimum coagulant type and dosage (Poly aluminium chloride, 15 mg L −1 ). The pilot plant performed best at a filtration rate of 15 m h −1 in a bed of commercial building silica sand with an average particle size of 0.93 mm, resulting in a net production of 0.103 m 3 h −1 of treated water. The removal efficiencies for apparent color, E. coli , turbidity and total suspended solids were 86.8 ± 2.3%, 86.8 ± 3.6%, 76.9 ± 6.9% and 68.7%, respectively. After a final stage of chlorine disinfection, the E. coli removal was higher than 99.7%. All the resulting parameters were within the recommended standards for nonpotable uses, such as landscape irrigation, dust and fire control, soil compaction, and street cleaning.
engineering, chemical, environmental
What problem does this paper attempt to address?