Full‐scale application of an electrochemical disinfection solution in a municipal drinking water treatment plant

José Waldir Sousa Filho,Giovanna Almeida Lenza,Marquele Amorim Tonhela,Karla Santos Araújo,David Maikel Fernandes,Geoffroy Roger Pointer Malpass
DOI: https://doi.org/10.1111/wej.12763
2021-11-04
Water and Environment Journal
Abstract:Abstract Few studies employ electrochemical technology for urban water disinfection. This paper presents the replacement of a Cl 2 gas system by an on‐site chlorine generation system (electrochemical disinfectant solution, EDS) and application at a water treatment plant. The study compares the Cl 2 gas and EDS systems over 36 months, with 18 months for Cl 2 gas and, after the implementation, 18 months for the EDS system (12‐month dry season and 6‐month wet season). Turbidity, residual Cl 2 , pH, total and faecal coliforms and DBPs were monitored. Turbidity was within legal limits and DBPs below both legal limits and limits of detection. For Cl 2 gas, residual Cl 2 suffered a decrease in wet and dry periods. However, the EDS maintained residual Cl 2 to the network tips without significant variations, with operational costs reduced by ~41%. The study demonstrates that on‐site Cl 2 generation can be employed for water disinfection for large urban areas with considerable economic and technical advantages.
environmental sciences,water resources,limnology
What problem does this paper attempt to address?