A pilot-scale wastewater reclamation system based on direct descending filtration and chlorine disinfection
Marília Vasconcellos Agnesini,Fernando Afonso Marrengula,Guilherme Sgobbi Zagui,Cristina Filomena Pereira Rosa Paschoalato,Murilo Daniel de Mello Innocentini
DOI: https://doi.org/10.1016/j.jece.2024.112165
IF: 7.7
2024-02-11
Journal of Environmental Chemical Engineering
Abstract:The development of cost-effective technologies for treating and disinfecting wastewater to a level that makes it economically valuable, environmentally sustainable, and health-safe for reuse is of utmost importance. In this study, a direct descending filtration pilot unit was designed, assembled, and tested within a municipal wastewater treatment plant to produce nonpotable reclaimed wastewater. Bench-scale tests were performed to define the optimum coagulant type and dosage (Poly aluminium chloride, 15 mg L −1 ). The pilot plant performed best at a filtration rate of 15 m h −1 in a bed of commercial building silica sand with an average particle size of 0.93 mm, resulting in a net production of 0.103 m 3 h −1 of treated water. The removal efficiencies for apparent color, E. coli , turbidity and total suspended solids were 86.8 ± 2.3%, 86.8 ± 3.6%, 76.9 ± 6.9% and 68.7%, respectively. After a final stage of chlorine disinfection, the E. coli removal was higher than 99.7%. All the resulting parameters were within the recommended standards for nonpotable uses, such as landscape irrigation, dust and fire control, soil compaction, and street cleaning.
engineering, chemical, environmental