Enhanced microfluidic multi-target separation by positive and negative magnetophoresis

Saud Khashan,Abdulkarem A. Odhah,Marwan Taha,Anas Alazzam,Mohamed Al-Fandi
DOI: https://doi.org/10.1038/s41598-024-64330-y
IF: 4.6
2024-06-12
Scientific Reports
Abstract:We introduce magnetophoresis-based microfluidics for sorting biological targets using positive Magnetophoresis (pM) for magnetically labeled particles and negative Magnetophoresis (nM) for label-free particles. A single, externally magnetized ferromagnetic wire induces repulsive forces and is positioned across the focused sample flow near the main channel's closed end. We analyze magnetic attributes and separation performance under two transverse dual-mode magnetic configurations, examining magnetic fields, hydrodynamics, and forces on microparticles of varying sizes and properties. In pM, the dual-magnet arrangement (DMA) for sorting three distinct particles shows higher magnetic gradient generation and throughput than the single-magnet arrangement (SMA). In nM, the numerical results for SMA sorting of red blood cells (RBCs), white blood cells (WBCs), and prostate cancer cells (PC3-9) demonstrate superior magnetic properties and throughput compared to DMA. Magnetized wire linear movement is a key design parameter, allowing device customization. An automated device for handling more targets can be created by manipulating magnetophoretic repulsion forces. The transverse wire and magnet arrangement accommodate increased channel depth without sacrificing efficiency, yielding higher throughput than other devices. Experimental validation using soft lithography and 3D printing confirms successful sorting and separation, aligning well with numerical results. This demonstrates the successful sorting and separating of injected particles within a hydrodynamically focused sample in all systems. Both numerical and experimental findings indicate a separation accuracy of 100% across various Reynolds numbers. The primary channel dimensions measure 100 μm in height and 200 μm in width. N52 permanent magnets were employed in both numerical simulations and experiments. For numerical simulations, a remanent flux density of 1.48 T was utilized. In the experimental setup, magnets measuring 0.5 × 0.5 × 0.125 inches and 0.5 × 0.5 × 1 inch were employed. The experimental data confirm the device's capability to achieve 100% separation accuracy at a Reynolds number of 3. However, this study did not explore the potential impact of increased flow rates on separation accuracy.
multidisciplinary sciences
What problem does this paper attempt to address?
### Problems the Paper Attempts to Solve The paper aims to develop an efficient, high-throughput microfluidic separation device that achieves multi-target separation of biological targets by utilizing positive magnetophoresis (pM) and negative magnetophoresis (nM) techniques. Specifically, the researchers introduce a magnetophoresis-based microfluidic technology that uses positive magnetophoresis (pM) to separate magnetically labeled particles and negative magnetophoresis (nM) to separate unlabeled particles. ### Main Research Content 1. **Principles of Magnetophoresis**: - Positive Magnetophoresis (pM): Separates magnetically labeled particles through the repulsive force generated by externally magnetized ferromagnetic wires. - Negative Magnetophoresis (nM): Separates unlabeled particles through the same repulsive force generated by magnetized ferromagnetic wires. 2. **Magnetic Configurations**: - Dual Magnet Configuration (DMA): Ferromagnetic wires are placed between two magnets, suitable for positive magnetophoresis mode. - Single Magnet Configuration (SMA): Ferromagnetic wires are magnetized by only one magnet, suitable for both positive and negative magnetophoresis modes. 3. **Performance Analysis**: - Studied the magnetic field, fluid dynamics, and forces acting on microparticles under different magnetic configurations. - Compared the separation performance and throughput of dual magnet configuration (DMA) and single magnet configuration (SMA) in both positive and negative magnetophoresis modes. 4. **Experimental Validation**: - Manufactured microfluidic devices using soft lithography and 3D printing technologies. - Experimentally validated the separation accuracy and throughput of the device at different Reynolds numbers. ### Key Findings - In positive magnetophoresis mode, the dual magnet configuration (DMA) exhibited higher magnetic gradient generation and throughput when separating 3 different particles. - In negative magnetophoresis mode, the single magnet configuration (SMA) demonstrated superior magnetic performance and throughput when separating red blood cells (RBCs), white blood cells (WBCs), and prostate cancer cells (PC3-9). - The channel depth of the device can be increased without affecting efficiency, thereby improving throughput. - Experimental results were consistent with numerical simulation results, validating 100% separation accuracy of the device at different Reynolds numbers. ### Application Prospects The microfluidic separation device developed in this study is highly adjustable and multifunctional, capable of handling various magnetic and non-magnetic targets. It is suitable for rapid, portable analysis in biomedical diagnostic and therapeutic applications.