Investigating the effect of water‐mixing nitrogen atmospheric pressure plasma jet on polyether‐ether‐ketone and time stability under different conditions

Xin Liu,Naiqiao Guan,Haiyang Shen,Zhongtao Zhang,Boxi Chen,Yuheng Li,Shungang Hua
DOI: https://doi.org/10.1002/app.50586
IF: 3
2021-02-12
Journal of Applied Polymer Science
Abstract:<p>Possessing excellent properties including good biocompatibility, high strength, and stiffness, polyether‐ether‐ketone (PEEK) has significant application values in medical and industrial fields. However, the relatively poor wettability and low adhesion limit its further applications. Atmospheric pressure plasma jet (APPJ) has been utilized for adjusting PEEK properties, but better hydrophilization effect and time stability after treatment are still urgently needed. In this paper, we employ a water‐mixing nitrogen (N<sub>2</sub><span class="icomoon"></span>H<sub>2</sub>O) APPJ to process PEEK, and surface wettability can be effectively improved (contact angle ~18° within 2 min, distance between sample and nozzle outlet: 10 mm) without inducing obvious microstructure damages. Additionally, after storing for 40 days, the sample treated by N<sub>2</sub><span class="icomoon"></span>H<sub>2</sub>O APPJ also possessed better wettability (~54°) compared with that treated by N<sub>2</sub> APPJ (~65°). On the basis of this low‐damage and high‐efficient modification method, we perform aging experiments under different conditions (different temperatures 25, −10°C; and low vacuum condition: 50 kPa) to determine a relatively optimum storing condition for this method. The experiment results indicate that low temperature and vacuum are conducive to retaining the plasma‐induced wettability (~34°). The treatment method and storing conditions for PEEK presented here may facilitate the application of PEEK in various fields.</p>
polymer science
What problem does this paper attempt to address?
The problem that this paper attempts to solve is that the polyetheretherketone (PEEK) material has limited its wider application in medical and industrial applications due to its poor surface wettability and adhesion. Specifically, the paper explores the use of a water - mixed nitrogen atmospheric - pressure plasma jet (N\(_2\)H\(_2\)O APPJ) to treat PEEK materials in order to improve their surface wettability and studies the time - stability of this treatment effect. In addition, the paper also determines a relatively optimal storage condition through aging experiments under different conditions (such as temperature and vacuum degree) to maintain the high wettability of the plasma - treated PEEK materials. The main contribution of the paper lies in providing an efficient and low - damage method to improve the surface properties of PEEK, and it is verified by experiments that storage at low temperature and under vacuum conditions can better maintain the wettability of the plasma - treated PEEK materials. These findings are of great significance for promoting the application of PEEK in various fields.