Experimental study on defects detection in GFRP laminates using lock-in infrared thermography technology

Qing-Ju Tang,Ze-Shen Qu,Gui-Peng Xu,Xin-Jie Tan
DOI: https://doi.org/10.2298/tsci230611041t
IF: 1.971
2024-01-01
Thermal Science
Abstract:To detect the debonding defect of glass fiber reinforced polymer laminate, the lock-in infrared thermography non-destructive testing system is built and the systematic testing research are conducted, and the effect of different geometrical parameters of debonding defects on the testing results are analyzed. Algorithms such as inter frame differential-multi frame cumulative average method, polynomial fitting-correlation coefficient method, and time-difference contrast method are used to process the image sequence, and signal-to-noise ratio and information entropy are defined as the parameters for evaluating the performance of algorithms.
thermodynamics
What problem does this paper attempt to address?