Developing and Testing High-Performance SHM Sensors Mounting Low-Noise MEMS Accelerometers

Marianna Crognale,Cecilia Rinaldi,Francesco Potenza,Vincenzo Gattulli,Andrea Colarieti,Fabio Franchi
DOI: https://doi.org/10.3390/s24082435
IF: 3.9
2024-04-11
Sensors
Abstract:Recently, there has been increased interest in adopting novel sensing technologies for continuously monitoring structural systems. In this respect, micro-electrical mechanical system (MEMS) sensors are widely used in several applications, including structural health monitoring (SHM), in which accelerometric samples are acquired to perform modal analysis. Thanks to their significantly lower cost, ease of installation in the structure, and lower power consumption, they enable extensive, pervasive, and battery-less monitoring systems. This paper presents an innovative high-performance device for SHM applications, based on a low-noise triaxial MEMS accelerometer, providing a guideline and insightful results about the opportunities and capabilities of these devices. Sensor nodes have been designed, developed, and calibrated to meet structural vibration monitoring and modal identification requirements. These components include a protocol for reliable command dissemination through network and data collection, and improvements to software components for data pipelining, jitter control, and high-frequency sampling. Devices were tested in the lab using shaker excitation. Results demonstrate that MEMS-based accelerometers are a feasible solution to replace expensive piezo-based accelerometers. Deploying MEMS is promising to minimize sensor node energy consumption. Time and frequency domain analyses show that MEMS can correctly detect modal frequencies, which are useful parameters for damage detection. The acquired data from the test bed were used to examine the functioning of the network, data transmission, and data quality. The proposed architecture has been successfully deployed in a real case study to monitor the structural health of the Marcus Aurelius Exedra Hall within the Capitoline Museum of Rome. The performance robustness was demonstrated, and the results showed that the wired sensor network provides dense and accurate vibration data for structural continuous monitoring.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
### Problems the Paper Aims to Solve The paper aims to develop and test a high-performance Structural Health Monitoring (SHM) sensor that integrates a low-noise MEMS accelerometer. Specifically, the paper attempts to address the following issues: 1. **Cost and Installation Convenience**: Traditional piezoelectric accelerometers, while reliable in performance, are costly, especially when multiple data acquisition points are needed. MEMS accelerometers, due to their significantly lower cost, ease of installation in structures, and lower power consumption, present a potential alternative. 2. **Data Quality and Reliability**: Although MEMS accelerometers have a cost advantage, their data quality and reliability need to be verified to meet the requirements of structural health monitoring. The paper evaluates the performance of MEMS accelerometers under static and dynamic conditions through laboratory tests and practical applications. 3. **Energy Consumption Optimization**: Traditional sensor nodes may consume a large amount of energy during long-term monitoring, leading to frequent battery replacements or recharging. The paper designs a low-power sensor node to reduce energy consumption and achieve long-term battery-free monitoring. 4. **Network and Data Management**: To achieve large-scale, dense structural health monitoring, a reliable network and data management system are required. The paper proposes a wired network-based architecture, including sensor nodes, gateways, switches, and routers, to ensure reliable data transmission and storage. 5. **Practical Application Verification**: The paper not only conducts tests in a laboratory environment but also performs actual deployment in the Marcus Aurelius Hall of the Capitoline Museums in Rome to verify the system's performance and reliability. Through these studies, the paper hopes to demonstrate that MEMS accelerometers can serve as a viable solution to replace expensive piezoelectric accelerometers and play an important role in structural health monitoring.