Development of Triaxial MEMS Digital Accelerometer on Structural Health Monitoring System for Midrise Structures

Jamie Eduardo C. Rosal,Meo Vincent C. Caya
DOI: https://doi.org/10.1109/hnicem.2018.8666311
2018-11-01
Abstract:Damage detection and characterization using nondestructive methods in structural and civil engineering progresses significantly in utilizing structural health monitoring techniques but, implementation issues still exist such as poorly calibrated sensors prompting low data accuracy. This study aims to measure the characteristics of the ADXL 345 accelerometer in the laboratory and during working conditions. Calibration technique used was a subwoofer method and yielded 96.3481% accuracy and measured the vibration on a particular building. Consequently, the system is capable of measuring frequency response and acceleration measurement that is important in structural health monitoring.
What problem does this paper attempt to address?