Feasibility Analysis of Tritium Measurement in the Aqueous Medium Based on a Plastic Scintillating Fiber Array

Wenyu Cheng,Linlin Zeng,He Zhou,Jie Liang,Ke Deng,Qin Zhang,Wei Liu
DOI: https://doi.org/10.1080/00295450.2024.2338508
IF: 1.667
2024-06-09
Nuclear Technology
Abstract:Tritium causes internal dose hazards to humans. Currently, tritium in the environment mainly comes from nuclear power plants, and tritiated water (HTO) is the main form of liquid emission. Therefore, online monitoring activity of tritium in the aqueous medium is vital for protecting human health, and it can warn of the operation status of nuclear power plants. In this paper, we present an improved structure of plastic scintillating fiber (PSF) and a PSF array design, and the detection parameters of PSF arrays with different radii and lengths under different radius detection chambers are simulated using Geant4. Based on the simulation results, the detector is designed, and the minimum detectable activity concentration (MDAC) of the detector is calculated. With calculated MDACs down to 3.09 Bq/L, the proposed design can meet the Chinese requirements for HTO release of inland nuclear power plants of <100 Bq∙L −1 . Therefore, the detector designed with a PSF array can be applied to online monitoring of tritium in the aqueous medium.
nuclear science & technology
What problem does this paper attempt to address?