First realization of LHW-plasma coupling feedback control for long pulse operation in EAST
Bojiang Ding,Guanghou Yan,Q P Yuan,Y C Li,Chenbin Wu,Jinhua Wu,Bin Cao,J H Yang,Miaohui Li,Mao Wang,Wendong Ma,Zege Wu,Wei Sun,Liang Liu,Lianmin Zhao,Huaichuan Hu,Jiafang Shan,Fukun Liu,Jinping Qian,X Gong
DOI: https://doi.org/10.1088/1741-4326/ad4806
IF: 3.3
2024-05-08
Nuclear Fusion
Abstract:In order to sustain good LHW (lower hybrid wave) -plasma coupling for long pulse plasma operation, it is the first time that the coupling feedback control is designed and realized in EAST through PID (Proportion Integration Differentiation) method by choosing RC (reflection coefficient of LHW power) as the reference for the feedback of gas puffing, including one pulse test and multi-pulse experiments. Experiments show that such feedback control can work correctly and keeps good LHW-plasma coupling effectively for long time, suggesting the possibility of feedback control application on LHW-plasma coupling in long pulse plasma. Furthermore, during the process of feedback control of multi-pulse SMBI (supersonic molecular beam injection), the stored energy changes from 29kJ to 58kJ, and the energy confinement factor (H89) increases from 0.98 to 1.45, implying a positive effect of coupling feedback on plasma performance. Experiments between SMBI puffing and the gas-puffing fed by piezoelectric valve near the antenna are further investigated, showing that the response time on RC with SMBI is faster than that by the piezoelectric valve and that SMBI puffing in the electric drift side of LHW antenna is a little quicker than that in the ion drift side. Studies suggest that such feedback control is effective for long pulse LHW-plasma coupling and the gas puffing by SMBI in the electric drift side of LHW antenna could offers an effective way to sustain good LHW coupling in steady state operation in future. Further optimization will be continued later.
physics, fluids & plasmas