A Theoretical and Experimental Study of a Piezoelectric Pump with Two Elastic Chambers

Xiaolong Zhao,Dingxuan Zhao,Qinghe Guo
DOI: https://doi.org/10.3390/s20205867
IF: 3.9
2020-10-16
Sensors
Abstract:The paper is a continuation of our work on the dynamic load in piezoelectric pumps. In the study, the dynamic load of liquid in the pipelines was proposed as a key factor that limits the output performance of piezoelectric pumps. To decrease the dynamic load, a piezoelectric pump with two elastic chambers was proposed in our previous published work. In this paper, the performance and key parameters of the piezoelectric pump with two elastic chambers were studied through theoretical analyses and experimental tests. After establishing the mathematical model of the piezoelectric pump with two elastic chambers, the paper theoretically analyzed the performance of the pump and the effect of different structural parameters on the performance. Then prototypes with a range of structural parameters were developed and tested. As revealed from the test results, the elastic chamber effectively decreased the dynamic load of the liquid in the pipelines and the flow rate of the prototype with two elastic chambers was higher than that of the prototype with one or no elastic chamber. However, the elastic chamber did not lead to the increase in the maximum output backpressure of the prototype. Adopting an elastic diaphragm exhibiting a smaller stiffness or a larger diameter could help decrease the dynamic load of the liquid. The elastic chamber more significantly impacted the flow rate of the piezoelectric pump with long pipelines. The pump chamber height had a significant effect on the output performance of the piezoelectric pump with two elastic chambers, which is consistent with the conventional piezoelectric pump. At the height of 0.2 mm, the flow rate of the prototype with two elastic chambers was peaked at 7.7 mL/min; at the height of 0.05 mm, the output backpressure reached the highest of 28.2 kPa. The dynamic load could decrease the amplitude of the piezoelectric vibrator, whereas the prototype with two elastic chambers could effectively reduce the impact of dynamic load on the piezoelectric vibrator. The flow rate decreased almost linearly with the backpressure. Under the same backpressure, the flow rate of the prototype with two elastic chambers was higher than that of the prototype without elastic chamber, and the flow rate difference between the two prototypes gradually decreased with the backpressure.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
What problem does this paper attempt to address?
The paper primarily aims to address the issue of decreased output performance of piezoelectric pumps when operating at high frequencies. Specifically, the research team focuses on how the dynamic load of the liquid within the pipeline affects the efficiency of the piezoelectric pump. The main issues presented in the paper are: 1. **Impact of Dynamic Load on Output Performance**: The study points out that the vibration of the liquid in the inlet and outlet pipelines generates a dynamic load, which increases the energy loss of the pump system, thereby reducing the output performance of the piezoelectric pump. 2. **Improvement Plan**: To reduce the impact of this dynamic load, the researchers designed a new type of piezoelectric pump with two elastic chambers (located outside the inlet and outlet valves, respectively). These elastic chambers can sever the rigid connection between the liquid in the pump chamber and the liquid in the pipeline, thereby reducing liquid vibration and consequently lowering the dynamic load. 3. **Theoretical Analysis and Experimental Verification**: By establishing a mathematical model for theoretical analysis and developing a series of prototype pumps with different structural parameters for experimental testing, the results show that the design with two elastic chambers can indeed effectively reduce the dynamic load and increase the pump flow rate. 4. **Impact of Structural Parameters**: The paper also explores the impact of different structural parameters (such as the thickness and diameter of the elastic diaphragm, the height of the pump chamber, etc.) on the pump performance. For example, reducing the height of the pump chamber helps to increase the output pressure, but an excessively low height can lead to significant pressure loss, thereby reducing the overall performance of the pump. In summary, the paper aims to address the negative impact of dynamic load on the output performance of piezoelectric pumps under high-frequency operating conditions by introducing a design with elastic chambers and to explore the impact of different structural parameters on the effectiveness of this solution.