Identification of Wind Load Exerted on the Jacket Wind Turbines from Optimally Placed Strain Gauges Using C-Optimal Design and Mathematical Model Reduction

Fan Zhu,Meng Zhang,Fuxuan Ma,Zhihua Li,Xianqiang Qu
DOI: https://doi.org/10.3390/jmse12040563
IF: 2.744
2024-03-28
Journal of Marine Science and Engineering
Abstract:Wind turbine towers experience complex dynamic loads during actual operation, and these loads are difficult to accurately predict in advance, which may lead to inaccurate structural fatigue and strength assessment during the structural design phase, thereby posing safety risks to the wind turbine tower. However, online monitoring of wind loads has become possible with the development of load identification technology. Therefore, an identification method for wind load exerted on wind turbine towers was developed in this study to estimate the wind loads using structural strain, which can be used for online monitoring of wind loads. The wind loads exerted on the wind turbine tower were simplified into six equivalent concentrated forces on the topside of the tower, and the initial mathematical model for wind load identification was established based on dynamic load identification theory in the frequency domain, in which many candidate sensor locations and directions were considered. Then, the initial mathematical model was expressed as a linear system of equations. A numerical example was used to verify the accuracy and stability of the initial mathematical model for the wind load identification, and the identification results indicate that the initial mathematical model combined with the Moore–Penrose inverse algorithm can provide stable and accurate reconstruction results. However, the initial mathematical model uses too many sensors, which is not conducive to engineering applications. Therefore, D-optimal and C-optimal design methods were used to reduce the dimension of the initial mathematical model and determine the location and direction of strain gauges. The C-optimal design method adopts a direct optimisation search strategy, while the D-optimal design method adopts an indirect optimisation search strategy. Then, four numerical examples of wind load identification show that dimensionality reduction of the mathematical model leads to high accuracy, in which the C-optimal design algorithm provides more robust identification results. Moreover, the fatigue damage calculated based on the load identification wind loads closely approximates that derived from finite element simulation wind load, with a relative error within 6%. Therefore, the load identification method developed in this study offers a pragmatic solution for the accurate acquisition of the actual wind load of a wind turbine tower.
oceanography,engineering, marine, ocean
What problem does this paper attempt to address?
The paper aims to address the challenge of wind load measurement encountered by offshore wind turbine towers during actual operation. Specifically, the objectives of the paper include: 1. **Developing a wind load identification method**: Estimating the wind load on the wind turbine tower through structural strain and achieving online monitoring of wind load. 2. **Simplifying the wind load model**: Simplifying the wind load on the wind turbine tower to six equivalent concentrated forces at the top of the tower and establishing an initial mathematical model based on dynamic load identification theory. 3. **Optimizing sensor placement**: Using C-optimal design and D-optimal design methods to reduce the number of sensors in the initial mathematical model and determine the optimal positions and orientations of the strain gauges. 4. **Improving accuracy and stability**: Verifying whether the initial mathematical model combined with the Moore-Penrose pseudoinverse algorithm can provide stable and accurate results, and demonstrating through numerical examples that the C-optimal design algorithm can provide more robust identification results. 5. **Fatigue damage analysis**: Comparing the fatigue damage calculated based on the wind load identification results with the finite element simulation results, with a relative error within 6%, thereby providing a practical method to accurately obtain the actual wind load on the wind turbine tower. Overall, this study provides new technical means for the online monitoring of wind load on offshore wind turbine towers, contributing to the improvement of the safety and reliability of structural design.