Experimental Evaluation of a Passive Upper Limb Exoskeleton for High Voltage Live-Line Operations

Dongwei Zhao,Song Wang,Shouqian Sun,Xuequn Zhang,Kimmo Vänni
DOI: https://doi.org/10.1109/ihmsc62065.2024.00049
2024-01-01
Abstract:In high-voltage live-line work, workers often need to hold insulating tubes and other tools for extended periods, leading to upper limb muscle strain, especially among inexperienced workers. Reducing muscle load can effectively prevent such hazards. This paper validates a newly designed passive upper limb exoskeleton through workspace analysis, biomechanical simulation, and filed experiment. The results demonstrate that the exoskeleton meets the movement space requirements of live-line workers. In the simulation environment, we made the model perform the lead connection task, the average muscle activation of the deltoid muscle when wearing the exoskeleton is reduced by 34.07%–55.56% compared to without the exoskeleton, and the average muscle activation of the trapezius muscle is reduced by 19.40%–25.63%. In live-line working experiments, the muscle activation of subjects decreased by 38.33% in the insulating protective cover construction task, 33.49% in the lead connection task, and 23.69% in the climbing down the pole task. Meanwhile, wearing the exoskeleton did not negatively impact task efficiency. These findings suggest that the exoskeleton can significantly reduce muscle strain without compromising productivity during high-voltage live-line work.