0.5-8.5 GHz Cryogenic Low Power Consumption Amplifiers for Superconducting SIS Mixer-based Water Vapour Radiometer Applications

Jie Liu,Xuan Zhang,Dong Liu,Zhenhui Lin,Junda Jin,Qijun Yao,Jing Li,Shengcai Shi
DOI: https://doi.org/10.1109/iws61525.2024.10713570
2024-01-01
Abstract:An ultra-wideband cryogenic-low-noise-amplifier (CLNA) was designed, fabricated and measured at the ambient temperature of 290K and 4K respectively. The amplifier exhibits a typical gain of 33±1.5dB and an average noise of 8.8K with total power consumption of 4mW at the temperature of 4K. To verify the feasibility of the cryogenic amplifier for the 183GHz water vapour radiometer based on superconducting Superconductor-Insulator-Superconductor (SIS) mixer, we measured the performance of the water vapour radiometer front-end using the amplifier following the SIS mixer as well, resulting in the average noise temperature of the radiometer front-end is about 110K. All the results indicated that the 0.5-8.5GHz CLNA developed in this paper makes it suitable for the radiometer and other application of radio astronomy, space science, atmospheric science and so on.