Octagonal Double Transformer SQUID Sensors with Large Input Inductance for Cryogenic Current Comparator

Da Xu,Qing Chen,Jinjin Li,Wenhui Cao,Wei Li,Kunli Zhou,Yunfeng Lu,Jianting Zhao,Qing Zhong
DOI: https://doi.org/10.1109/cpem61406.2024.10645993
2024-01-01
Abstract:Superconducting quantum interference devices (SQUIDs) with large input inductance and octagonal double transformer were designed and fabricated using Nb/Al-AlO x /Nb Josephson junctions for cryogenic current comparator (CCC). A 30-turn input coil of 1.5 µH is coupled to a large octagonal transformer of 3.6 nH. The counterpart of transformer is a 1.5turn coil of 3.0 nH coupled to a second-order gradiometric SQUID of 64 pH. The octagonal double transformer makes lowinductance SQUID easily match to the large-inductance input coil. At 1 kHz, a current sensitivity of 1.1 µA/Φ 0 , a flux noise of 3.7 µΦ 0 /√Hz and a current noise of 4.1 pA/√Hz were achieved at 4.2 K. Another SQUID sensor with 10-turn input coil of 0.5 µH coupled to a large octagonal transformer of 6.0 nH, which is coupled to a first-order gradiometric SQUID of 580 pH, achieves a lower current sensitivity of 0.5 µA/Φ 0 and a current noise of 5.9 pA/√Hz.
What problem does this paper attempt to address?