Ultralow Degradation Cold Start of Proton Exchange Membrane Fuel Cell with Alternating Hydrogen Pump Method

Wenbo Shi,Dewei Li,Kai Niu,Ruoxi Yang,Haosen Xu,Jianbo Zhang
DOI: https://doi.org/10.1016/j.ijhydene.2024.08.309
IF: 7.2
2024-01-01
International Journal of Hydrogen Energy
Abstract:Cold start impedes widespread diffusion of fuel cell vehicles (FCVs) in regions with temperatures below zero. Alternating hydrogen pump (AHP) method, distinguished by its unlimited ohmic heating capability without generating water, has been shown to be a quick and efficient method of cold starts in both single cell and short stacks. In this paper, we continue to examine possible degradation with this novel method. For this purpose, we carefully designed three experiments with different levels of stress, aimed to separate the contribution to any degradation from major factors. It was found there was no significant difference among the three cases. AHP method incurred minimal degradation after 3600 times of equivalent -30 degrees C cold starts. This study concludes that AHP method is not only quick and efficient, but also highly durable, hence AHP is a promising alternative cold start strategy with great potential to facilitate the diffusion of FCVs.
What problem does this paper attempt to address?