Optimization and Design of Low-Voltage and High-Current Point-of-Load Converter under 48V Bus Architecture

Jiajia Guan,Jin Wen,Shuangxi Zhu,Zongheng Wu,Cai Chen,Yong Kang,Yue Wu,Zhipeng He
DOI: https://doi.org/10.30420/566262362
2024-01-01
Abstract:The data center power supply architecture is changing from 12V to 48V, and the Point-of-Load (PoL) converter is facing the problem of how to achieve a high step-down ratio and high efficiency under high current. Based on the two-stage architecture, this paper proposed a method to improve the efficiency of the converter by optimizing the switching frequency and the phase number of Buck. Finally, a 48V-1V/200W prototype was designed based on the optimization results. Under the rated conditions, the prototype achieves peak efficiency of 91.7%, closed-loop control error less than 1% and power density of 52W/in3.
What problem does this paper attempt to address?