Spatial Characteristics of Local Current Density Distribution and the Impact of Relative Humidity During Airborne Ammonia Contaminates PEMFC

Yuan Jing,Yunyang Ma,Weichen Ji,Xin Cai,Rui Lin
DOI: https://doi.org/10.1016/j.ijhydene.2024.08.119
IF: 7.2
2024-01-01
International Journal of Hydrogen Energy
Abstract:Airborne NH3 is a factor in the degradation of proton exchange membrane fuel cell (PEMFC) performance and lifetime. Herein, the spatial characteristics of PEMFC contaminated with NH3 in galvanostatic and potentiostatic states are investigated by analyzing the local current density, and the effect of relative humidity (RH) during NH3 contaminates PEMFC is studied by durability curve, polarization curve, and electrochemical impedance spectroscopy testing. The results show that NH3 leads to an obvious voltage attenuation along with a significant increase in cathode activation and mass transfer impedance. The distribution of relaxation time (DRT) results show that the anode activation is poisoned by cathode NH3. The voltage attenuation and impedance increase caused by NH3 are negatively correlated with the RH. At 0%, 25%, 50%, and 75% RH, the voltage decays 19.4%, 10.7%, 8.4%, and 8.1%. The current density attenuation is more severe in potentiostatic state, with a rate of 41.2% and more than 600 mA center dot cm(-2) in the inlet region, which could be related to the low NH3 concentration and high amount of product water promoting the dissolution of NH3 in the intermediate and outlet regions. Consequently, it is recommended that the cell be operated in galvanostatic state with high RH to alleviate the effect of NH3 and resulting inhomogeneous performance.
What problem does this paper attempt to address?