Comparative Study of Different Layouts in the Closed-Brayton-Cycle-Based Segmented Cooling Thermal Management System for Scramjets
Chaolei Dang,Jing Xu,Zhichao Chen,Kunlin Cheng,Jiang Qin,Guodong Liu
DOI: https://doi.org/10.1016/j.energy.2024.131646
IF: 9
2024-01-01
Energy
Abstract:The segmented cooling thermal management system based on the closed-Brayton-cycle (CBC) is an excellent technology for thermal protection and power generation of scramjets. In this paper, a comparative study is conducted to investigate the system performance under different supercritical carbon dioxide CBC layouts. A zero-dimensional thermodynamic model was established to analyze the effects of compressor inlet temperature (T1), T 1 ), turbine inlet temperature (T3), T 3 ), and compressor outlet pressure (p2) p 2 ) on fuel mass flow rate for cooling (mf) m f ) and net power (Pnet). P net ). A quasi-one-dimensional flow and heat transfer model was developed to study the cooling effectiveness. Results indicate that higher T 3 and p 2 reduce mf f while increasing P net in the simple layout (SL) and simple recuperated layout (SRL). However, in the recompressing layout (RCL), the effects ofT1, T 1 , T 3 , and p 2 on mf f are more complex due to the split ratio. Moreover, RCL has the lowest maximum wall temperature among the three layouts. Finally, after optimization, RCL has the lowest mf f about 0.332 kg/s, which is a 19.8 % reduction compared to the regenerative cooling system. Correspondingly, RCL achieves the highest P net , reaching 109.89 kW. In general, the recompressing layout is most suitable for the CBC-based segmented cooling thermal management system for scramjets.