Signal Processing Method of Ultrasonic Gas Flowmeter Based on Transit-Time Mathematical Characteristics

Junyang Zhou,Peng Wang,Ruibing Wang,Zhenyu Niu,Kai Zhang
DOI: https://doi.org/10.1016/j.measurement.2024.115485
IF: 5.6
2025-01-01
Measurement
Abstract:To address the issue of timing errors caused by attenuation and jitter in the echo signal with the conventional threshold method, this paper presents a signal processing method for ultrasonic gas flow meters based on the mathematical characteristics of transit time. First, an improved weighted recursive filtering algorithm based on the mathematical characteristics of transit time is proposed. Then,based on the aforementioned filtering algorithm, a feedback-type threshold adjustment method has been proposed. Finally, the results for the flow meter meeting the performance criteria for a Class 1 accuracy ultrasonic gas flow meter at range of 2 similar to 300 m(3)/h. This signal processing technique can be implemented at comparatively low cost on existing conventional fixed-threshold flow measurement infrastructures, with the potential to significantly improve accuracy and reliability.
What problem does this paper attempt to address?