Self-assembled copper oxide nanoflakes for highly sensitive electrochemical xanthine detection in fish-freshness biosensors
G. Sriramulu,Rahul Verma,Kshitij RB Singh,Pooja Singh,Ch. Shilpa Chakra,Sadhucharan Mallick,Ravindra Pratap Singh,K. Sadhana,Jay Singh
DOI: https://doi.org/10.1016/j.molstruc.2024.137640
IF: 3.841
2024-02-03
Journal of Molecular Structure
Abstract:Xanthine presence in meat indicates the freshness of the fish meat, whereas, in urine and serum, it indicates potentially lethal health issues for humans. The investigation's primary emphases are food safety and human health, both of which are significant in perspective of the recent, rapidly increasing industrialization. Fish is occasionally sold globally due to its high protein content and availability of omega-3 fatty acids. However, with today's anxious lifestyle, the consumption of packaged meals has increased dramatically, and evaluating how much fresh fish has an important impact on the food industry and consumers has substantial health concerns. Therefore, one of the most important areas of concern is the early identification of fish freshness. In addition to providing information on the freshness of the meat, measuring the amount of xanthine in serum or urine may help determine the cause and treatment of several physiological illnesses, including xanthinuria, hyperuricemia, and kidney problems. Therefore, this work employed a temperature-based synthesis in combination with microwave-hydrothermal techniques to synthesize CuO nanoflakes, thereby solving the problem of fish freshness. Further, numerous techniques, including structural and morphological studies of as-prepared nanomaterial. Additionally, the surface of CuO nanoflakes that have been electrophoretic deposited (EPD) on an ITO electrode surface and xanthine oxidase (XOx) immobilized by the drop cast method. A detailed analysis was conducted on the amperometric response of the XOx/CuO/ITO bioelectrode with many factors such as xanthine concentration, stability, reusability, operating pH, and scan rate analysis. It was discovered that the presence of the CuO matrix caused the charge transfer rate (Ks) between the electrode and immobilized XOx to be 1.472 s −1 . The maximal current response (0.729 mA) was observed at 40 s, with sensitivity 8.6 × 10 −3 mA/μMcm 2 and a limit of detection (LOD) of 0.756 μM of the XOx/CuO/ITO bioelectrode. As a result, the assembled XOx/CuO/ITO bioelectrode shows great promise for accelerating the development of a biosensor for monitoring the xanthine concentration in the fish to be reliable for food and healthcare.
chemistry, physical