Comparison with Calculating the Coefficient of Local Head Loss Models for Inverted Siphons

Zhongjing Wang
2006-01-01
Abstract:The calculation of local head loss in a pressured curved tube is very important for the design of the construction of inverted siphon.Among them mainly affected by geometric parameters including the angle of bend,the relative radius of curvature,and the aspect ratio of cross section.This paper presents verifications of existing local-head-loss models by using experimental data from physical models and analysis of the influence of tube geometries on the coefficient of local head loss.It shows that the coefficient of local head loss in elbows with sharp corners is not larger than that in bends in the case that the angle of bend is less than 17 degrees.Other conditions being equal,elbows with rounded corners offer smaller local head loss than elbows with sharp corners do.In the design of water diversion projects with low head and large discharge,elbows with sharp corners could be applied to inverted siphons for the convenience of construction and for the advantage of lower local head loss.
What problem does this paper attempt to address?