Studying on Comprehensive Details for Reducing Front and Back Wall Lateral Stiffness Difference of Rural Masonry Buildings

Dongdong Zhang
2013-01-01
Abstract:This paper proposed three seismic details for reducing front and back wall lateral stiffness difference,improving front wall integrity which be weaken by door and window openings.The three seismic details are adding L shaped tie column at the two side of front wall,substituting single lintel with continuous lintel and embedded steel into front wall below the windows.The earthquake response is comparative analyzed for a typical North-West rural masonry building with different seismic details.The results show that the seismic details would reduce torsional seismic response,avoiding local damage near two sides of lintels and reducing and delaying the wall crack below the windows.The new seismic details have few influences on base horizontal earthquake force.In short,the new seismic details are very effective for improving seismic performance of rural masonry buildings.
What problem does this paper attempt to address?