Treatment of Distal Tibiofibular Syndesmosis Injury with Endobutton Plate-Cable System Rebuilding Complex Body of Distal Tibiofibular Syndesmosis

Qian Wang
2013-01-01
Abstract:Objective To explore the treatment effect of the distal tibiofibular syndesmosis injury with Endobutton plate-cable system for rebuilding the complex body of distal tibiofibular syndesmosis.Methods A total of 15 patients with ankle fractures of tibial phil joint damage were enrolled,included 10 males and 5 females,who were aged 22-43 years old with a mean age of 32.3,all cases was performed Endobutton button-cable system fixation of ankle fracture with distal tibiofibular syndesmosis injury.After follow-up and standard ankle function score,the curative effect of the treatment was evaluated.Results All of them were followed up for 12-19 months(mean 14.2 months).The postoperative X-ray film of ankle mortise was normal.Curative effect was scored by American Orthopaedic Foot and Ankle Surgeons(AOFAS) ankle function score system,10 cases were excellent,and 4 cases good.There was no failure of tibiofibular syndesmosis fixation.Conclusion It is demonstrated that Endobutton button-cable system for ankle fracture with tibiofibular syndesmosis injury could recover the normal motion function and reduce the recovery time,it could also avoid the breakage of internal fixation and other complications.
What problem does this paper attempt to address?