Treatment of Ankle Joint Fracture with the Distal Tibiofibular Syndesmosis Injury by Improved Endobutton System Ligament Reconstruction Technique

Qian Wang
2014-01-01
Orthopedics
Abstract:Objective To explore the curative effectiveness of Endobutton Plate-cable system rebuilding the complex body of distal tibiofibular syndesmosis for the distal tibiofibular syndesmosis injury.Methods The patients with ankle fracture with the distal tibiofibular syndesmosis injury were treated by the Endobutton button-cable system fixation,and the curative effectiveness was compared with that by metal screws previously used.Through the follow-up and standard of the ankle function score,the curative effectiveness was evaluated.Results Twenty-five patients were followed up in Endobutton group for 24-32(26.2±2.4)months.The ankle hole was normal under the X-ray examination.According to the American Orthopaedic Ankle Surgery Association(AOFAS)ankle function score,curative effectiveness was excellent in 17 cases,and good in 8 cases.In metal screw group(n=18),the follow-up time was 18-20(16.2±3.4)months.Cuarative effectiveness was excellent in9 cases,and good in 6 cases,and fair in 3 cases.The curative effectiveness in the Endobutton group was more satisfactory than in the metal screw group.Conclusion The Endobutton button-cable system fixation of the ankle fracture with the distal tibiofibular syndesmosis injury recovers the normal motion function of the shank phil joint and functions exactly.
What problem does this paper attempt to address?