Preliminary Design of a Triggerless Readout System for CDEX-100 HPGe Detector Array

Jingjun Wen,Lin Jiang,Xiaowei Guo,Tao Xue,Jianmin Li,Yinong Liu
DOI: https://doi.org/10.1109/nss/mic44845.2022.10399235
2022-01-01
Abstract:The experiments based on germanium detectors which can explore low energy regions play an important role in the weekly interacting massive particles (WIMP) searching. CDEX-100 experiment aiming at the direct detection of light dark matter contains 100-kilogram HPGe detectors and will be held in CJPL-II underground laboratory. A preliminary design of a trigger-less readout system designed for CDEX-100 is introduced in this paper. The system can provide 128 sampling channels with 125 MSPS sampling rate and 16-Bit vertical resolution and use 2×PCIe 3.0×16 links which support 30GB/s transmission bandwidth for data uploaded. Commonly, in order to establish the energy threshold, the readout system will define the trigger level at a fixed number of baseline standard deviations (σ) above the baseline level, typical 5σ or more. However, this readout system can support triggerless readout of all sampling channels through ultra-high transmission bandwidth and on-line lossless data compression algorithms like Huffman coding. Then, it can provide lower energy threshold data for physical analysis to help the rare event searches.
What problem does this paper attempt to address?