Determination of Morphine in Human Plasma by Reversed-Phase Ion-Pair HPLC

Yan Liang
2003-01-01
Abstract:OBJECTIVE To establish an reversed-phase ion-pair HPLC for determination of morphine in human plasma. METHODS Morphine was extracted from human plasma using chloroform,separated on a Kromasi l C 18 analytical column ( 150 mm × 4.6 mm ).The mobile phase was 0 .04% sodium 1-heptantesulfonnate in water ( 0.1% acetic acid ) -methanol( 77∶23).pH 4.0 .Internal standard was xanthinol nicotinate, the wavelength of detection was set at 205 nm . RESULTS Linearity was verified from 20 to 1000 μg ·L -1 . The average recovery of morphine was 99.7% .CONCLUSIONS This method is simple, rapid and accurate for quantitative analysis of morphine in human plasma.
What problem does this paper attempt to address?