Determination of morphine3-glucuronide,morphine and O6-monoacetylmorphine in urine and plasma by LC-MS/MS with molid phase extraction

Yu Xiaowei,Wang Mei,Tan Xiaohui,Zhang Daming
DOI: https://doi.org/10.13618/j.issn.1001-5728.2013.03.017
2013-01-01
Abstract:Objective To use the method which can accurately measure the metabolites of heroin(including morphine,morphine3-glucuronide and O6-Monoacetylmorphine) in urine and plasma by LC-MS/MS with solid-phase extraction.Methods the samples were extracted by BAKERBONDTM spe Octadecyl(C18) Disposable Extraction Columns 3cc 500mg and then detected by LC-MS-MS,quantification of compounds was achieved using multiple reactionmonitoring(MRM) incorporating the use of deuterated O6-Monoacetylmorphine as internal standards.Results Limits of Detection(LOD) were 1.24pg for M3G,6.71pg for morphine and 0.47pg for O6-Monoacetylmorphin in urine and 1.5pg for M3G,8.21pg for morphine and 0.52pg for O6-Monoacetylmorphin in plasma.In urine the recoveries for M3G,morphine,O6-Monoacetylmorphine were 82.25±12.25%、93.75±13.25%、88.70±11.90% respectively,and in plasma were 89.85±21.15%,73.70±17.90%,90.10±3.90%.Conclusion The method is suitable for extraction,purification and quantitative analysis of morphine,morphine3-glucuronide and O6-Monoacetylmorphine both in human urine and plasma.
What problem does this paper attempt to address?