Simultaneous Determination of Major Phytocannabinoids, Their Main Metabolites, and Common Synthetic Cannabinoids in Urine Samples by Lc-Ms/Ms

Xiaoru Dong,Liliang Li,Yonghong Ye,Lixing Zheng,Yan Jiang
DOI: https://doi.org/10.1016/j.jchromb.2016.08.002
IF: 3.318
2016-01-01
Journal of Chromatography B
Abstract:Simultaneous determination of major phytocannabinoids (THC, CBD, CBN), their main metabolites (11-OH-THC, THC-COOH, THC-COOH-glucuronide) and common synthetic cannabinoids (HU-210, JWH-018, JWH-073, JWH-250) remains an issue in forensic toxicology. The present study has developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to simultaneously detect the above 10 analytes in human urine samples. The chromatographic separation was performed on an ACQUITY UPLC (R) BEH Phenyl 1.7 mu M (2.1 x 100mm) column, using a mobile phase consisting of 0.1% formic acid in water and acetonitrile at a flow rate of 0.3 mL/min in gradient elution mode. The limit of detection (LOD) and limit of quantification (LOQ) of all analytes were 0.01-0.5 ng/mL and 0.05-1 ng/mL, respectively. The assay was linear from LOQ to 100 ng/mL for phytocannabinoids, their main metabolites and HU-210, and from 0.05 to 50 ng/mL for JWH-250, JWH-018 and JWH-073. The extraction recoveries were over 50% and the matrix effects were between 59.4% and 100.1%. The accuracy and precision were <10.4% of bias and <10.5% of relative standard deviation (RSD), respectively. The developed method was applied to 5 urine samples from real caseworks, and the results that THC metabolites together with synthetic cannabinoids were detected demonstrated the effectiveness of our method. (C) 2016 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?