Resolution Improvement in a High-Power Magnetic Resonance Imaging Gradient Power Amplifier
Keqiu Zeng,Gert Rietveld,Saijun Mao,Hui Yu,Liguo Wang,Kun Liu,Zhiding Zhou,Jelena Popovic-Gerber
DOI: https://doi.org/10.1109/tpel.2022.3162385
IF: 5.967
2022-01-01
IEEE Transactions on Power Electronics
Abstract:High-resolution gradient power amplifiers are required to generate high-fidelity gradient fields in magnetic resonance imaging (MRI) systems. Various aspects of gradient power amplifiers have been the subject of research in the past years, however, systematic analysis and design methods for its resolution improvement have not been sufficiently addressed. This article addresses this research gap with comprehensive analysis and design methods for resolution improvement. First, a method for systematic resolution characterization of the MRI gradient power amplifier with gradient coil is proposed. Second, noise modeling with respect to the critical aspects in the system resolution degradation is developed and discussed. Third, the resolution improvement methods of bandwidth optimization, pseudorandom code modulation, and utilizing silicon carbide (SiC) switching power devices are proposed and analyzed, achieving a resolution at the one part in <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="3.379ex" height="2.676ex" style="vertical-align: -0.338ex;" viewBox="0 -1006.6 1454.9 1152.1" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMAIN-31"></use> <use xlink:href="#MJMAIN-30" x="500" y="0"></use> <use transform="scale(0.707)" xlink:href="#MJMAIN-36" x="1415" y="557"></use></g></svg></span> level. Finally, the resolution improvement methods are experimentally validated in a 1000 V/400 A SiC gradient power amplifier. The experimental results show a 3.6 times reduction in the peak spurious signals and resolution improvement at all current levels and pulse lengths, compared to a conventional insulated gate bipolar transistor GPA. These results prove the validity of the proposed methods for resolution improvement in a high-power MRI gradient power amplifier, enabling future high-power and high-resolution amplifier designs.<svg xmlns="http://www.w3.org/2000/svg" style="display: none;"><defs id="MathJax_SVG_glyphs"><path stroke-width="1" id="MJMAIN-31" d="M213 578L200 573Q186 568 160 563T102 556H83V602H102Q149 604 189 617T245 641T273 663Q275 666 285 666Q294 666 302 660V361L303 61Q310 54 315 52T339 48T401 46H427V0H416Q395 3 257 3Q121 3 100 0H88V46H114Q136 46 152 46T177 47T193 50T201 52T207 57T213 61V578Z"></path><path stroke-width="1" id="MJMAIN-30" d="M96 585Q152 666 249 666Q297 666 345 640T423 548Q460 465 460 320Q460 165 417 83Q397 41 362 16T301 -15T250 -22Q224 -22 198 -16T137 16T82 83Q39 165 39 320Q39 494 96 585ZM321 597Q291 629 250 629Q208 629 178 597Q153 571 145 525T137 333Q137 175 145 125T181 46Q209 16 250 16Q290 16 318 46Q347 76 354 130T362 333Q362 478 354 524T321 597Z"></path><path stroke-width="1" id="MJMAIN-36" d="M42 313Q42 476 123 571T303 666Q372 666 402 630T432 550Q432 525 418 510T379 495Q356 495 341 509T326 548Q326 592 373 601Q351 623 311 626Q240 626 194 566Q147 500 147 364L148 360Q153 366 156 373Q197 433 263 433H267Q313 433 348 414Q372 400 396 374T435 317Q456 268 456 210V192Q456 169 451 149Q440 90 387 34T253 -22Q225 -22 199 -14T143 16T92 75T56 172T42 313ZM257 397Q227 397 205 380T171 335T154 278T148 216Q148 133 160 97T198 39Q222 21 251 21Q302 21 329 59Q342 77 347 104T352 209Q352 289 347 316T329 361Q302 397 257 397Z"></path></defs></svg>
engineering, electrical & electronic