Design and Analysis of Cryogenic System for the Rotor of a 15 Mvar HTS Synchronous Condenser

Huafang Wu,Lei Wang,Hongyi Qu,Cong Wang,Qiuliang Wang
DOI: https://doi.org/10.1109/asemd59061.2023.10369141
2023-01-01
Abstract:This paper describes the design and analysis of the cryogenic system of a 15 Mvar high-temperature superconducting (HTS) dynamic synchronous condenser rotor. The excitation winding of the condenser rotor is wound with HTS strip, and the HTS windings are cooled by 20 K cold helium gas flowing inside. To maintain the stability of the low-temperature environment inside the rotor and reduce system heat loss, special materials such as epoxy fiberglass and insulation film will be used for insulation treatment. Calculate the overall heat loss of the rotor, and then simulate the cooling effect of helium gas in the rotor. The simulation results show that the maximum temperature of the coil is 25.8 K, which meets the low temperature requirements of HTS materials.
What problem does this paper attempt to address?