Numerical Simulation on Smoke Control for Extra-Long Tunnel Fires

Wenbo Liu,Junmei Li,Yanfeng Li
2023-01-01
Abstract:Abstract Based on an actual project in Beijing, this article investigates the effect of smoke control strategies on smoke extraction efficiency under different fire source locations of the point smoke extraction system in extra-long tunnels using Airpak software. The results show that when a fire occurs in a tunnel, the smoke extraction efficiency of the tunnel smoke extraction system varies greatly depending on the location of the fire source and the adoption of different smoke extraction strategies. Due to the suction of the smoke exhaust shaft fan, the relative distance between the electric smoke exhaust valve and the entrance of the tunnel is close, which will cause the smoke exhaust valve within a certain range to be plug-holing, seriously affecting the smoke exhaust effect of the smoke exhaust system. Smoke exhaust valve beyond this range, although not occurring plug-holing the smoke exhaust efficiency is also relatively low, by changing the opening strategy of the smoke exhaust valve can effectively improve the smoke exhaust valve plug-holing, so as to improve the smoke exhaust efficiency.
What problem does this paper attempt to address?